Electronic Theatre Controls PARADIGM Especificaciones Pagina 55

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 96
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 54
3 Programming 50
Dimming Control Menu
Set Levels
Step 1: Use the touch wheel to scroll to “Set Levels” from within the “Dimming Control”
menu and press enter ( ). The Set Levels menu list will display.
Step 2: Use the touch wheel to scroll through the list to select a specific dimmer or use
the alpha-numeric button pad and the “and/thru” functions to select specific or a
range of dimmers. Press enter ( ) to accept the selection. The focus changes
to the level value field.
Step 3: Use the touch wheel to scroll, or the alpha-numeric button pad, to enter a specific
level value for the selected dimmers. This value can be between zero
(displayed as --) and 100% (displayed as FL). Press enter ( ) to accept the
selection.
Step 4: When all dimmers are set to the desired level, press back ( ) to return to the
“Dimming Control” menu.
Step 5: When you exit the “Set Levels” menu, you will be prompted for confirmation if you
would like to “Release Set Levels”. Selecting “Yes” returns all set levels to the
default value. Selecting “No” causes all set levels to remain until released.
Note:
“NA” indicates a dimmer that cannot be set to a level such as a CC20.
Note:
Dimmers that are controlled from the “Set Levels” action cannot be controlled from
the architectural system, DMX, or sACN until they have been released.
Dimming Control
1 Set Levels
2 Dimmer Check
3 Release Set Levels
Set Levels
1 55 2 -- 3 FL
4 -- 5 50 6 --
7 50 8 FL 9 --
10 50 11 25 12 FL
13 NA 14 NA 15 FL
16 -- 17 FL 18 75
19 -- 20 50 21 50
1 and 5 thru 12
1 55 2 -- 3 FL
4 -- 5 55 6 55
7 55 8 55 9 55
10 55 11 55 12 55
13 NA 14 NA 15 FL
16 -- 17 FL 18 75
19 -- 20 50 21 50
Vista de pagina 54
1 2 ... 50 51 52 53 54 55 56 57 58 59 60 ... 95 96

Comentarios a estos manuales

Sin comentarios