(13) The control module shall be capable of monitoring and displaying incoming line voltage
for all three phases on the LCD. With installed current sensors, the same display shall
show amperage on each phase.
(14) English, French, German and Spanish language support shall be standard in the
control module.
(15) The control module shall support 4 levels of security access. The user shall to able to
program passwords that restrict access, preventing unauthorized use of higher-level
functions by unauthorized personnel.
1. Level 4: Administrator - shall have full access
2. Level 3: Super User – shall be able to access by circuit number, change
module and change rack types.
3. Level 2: User – shall be able to access by dimmer number
4. Level 1: Guest – shall be able to access “about” information
E) Standard Feedback:
(1) System and Rack messages shall include, but not be limited to, the following:
1. DMX port A or B has an error or has failed
2. Network has an error or has failed
3. Phase A, B or C is below 90 volts
4. Phase A, B or C is above 140 volts
5. Phase A, B or C did not start because it was below 90V or above 140V at
power up
6. Phase A, B or C voltage headroom warning
7. Frequency is not 50 or 60 Hz
8. Rack shutting down due to air flow loss
9. Ambient temperature is below 0C/32F
10. Ambient temperature is above 40C/104F
11. Rack shutting down - ambient temperature exceeds 46C/115F
12. Configuration memory error
(2) About display shall allow monitoring of system, rack or dimmer status.
(3) About System shall provide information about Panic circuits, Preset looks, and System
name.
(4) About Network shall provide IP address, gateway and net mask.
(5) About Rack General shall provide information about rack name, ambient temperature,
air filters and rack type.
(6) About Rack Power shall provide information about power type, rack voltages, current
per phase (only with current transformers), under voltage warnings.
(7) About Rack Data shall provide status for DMXA, DMXB, EDMX and Network activity.
(8) About Dimmer shall provide information about dimmer type, location, output level,
control source, scale voltage, mode and curve.
F) Advanced Feedback:
(1) Sensor's Advanced Features (AF) option shall add an additional sensor in the
individual dimmer modules. This option shall allow monitoring of current and output
voltage on a dimmer-by-dimmer basis and provide information on lamp burnouts,
dimmer status, and input voltages.
(2) The control module shall allow the user to record the loads of all AF dimmers in the
system. The control module shall, during operation, test each AF dimmer, determine its