174 Chapter 14 Lists and spreadsheets
Note the following with regard to defaults in the Submaster List display:
• Pile-on is the default type for a newly defined submaster.
• Bump status does not display unless changed from the default, which
is “enabled.”
• Dwell time defaults to “manual.”
• Rate does not display unless changed from the default, which is 100.
Editing submasters
Changes made to a submaster in the Submaster List are immediately
recorded. Edit in the Submaster List as follows.
77
Keystrokes: Actions:
1. Press [Blind]. Selects Blind display
2. Press[Sub] [S2], Sub List. Displays Submaster List
Select submaster number(s)
3. Press [1][3] [Enter]. Selects submaster 23. Prompt reads:
Select bump status and press
ENTER
(1=enabled, 2=disabled, 3=solo)
4. Press [1] [Enter].
a
a.
If not changing the bump status, for example if the submaster
is already enabled, you may just press [Enter].
Enables bump status for the
submaster. Prompt reads:
Enter upfade time
5. Press [5] [Enter]. Specifies 5 second upfade time
Prompt reads:
Enter dwell time
(For hold or manual operation, press
CLEAR until desired setting appears)
6. Press [1][5] [Enter]. Specifies 15 seconds dwell time
Prompt reads:
Enter downfade time
77.
Alternatively, you may press [Type] or [Time] keys to reach the field you want.
Navigation and Feedback - Submaster List
[S]
±
Select a submaster XXX
Select a field XX
White row selected submaster
Yellow field selected field