48 Chapter 4 Patching channels
Setting dimmers to Dimmer Doubling
ETC’s Dimmer Doubling technology can increase the controllable circuits
of a 115 volt, 60 Hz dimming system.
23
Dimmer Doubling converts the
output of a single ETC Sensor or L86 dimmer into two separate signals.
Both signals then provide discrete levels for two ETC Source Four lights.
24
You must configure the console by setting the mode of the dimmer and
the dimmer’s port before the dimmer will function in Dimmer Doubling
mode. Each dimmer and port is set individually. Before patching, set the
port mode with the procedure given under Setting the port to Dimmer
Doubling, page 313.
When a dimmer is doubled, it is functionally split into two dimmers that
are distinguished by A and B. For example, dimmer 1 becomes dimmer
1A and dimmer 1B. For each doubled port, the A components of each
dimmer are controlled by DMX512 outputs 1-256 and the B components
of each dimmer are controlled by DMX512 outputs 257-512. The console
represents doubled dimmers in the Patch display as dimmers in the range
1-256, parts A and B.
If a channel was patched to the dimmer before it was doubled, the
channel is assigned to both the A and B parts, thus keeping the number
of controlled circuits the same rather than doubled. To assign the doubled
parts of a dimmer independently, see Creating a custom patch, page 37.
Set dimmers to doubled with the procedure below.
23.
Dimmer Doubling is available only for ETC dimming systems operating nominally
at 115 volts, 60 Hz. It is not available for systems operating at other voltages or
frequencies.
24.
The Source Four lights should be running 77V HPL lamps when operated by a
doubled dimmer.
Keystrokes: Action:
1. Press [Patch]. Selects Patch display
2. Press [Dim] [1][8] [Thru]
[3][5].
a
a. Often there is no need to press [Dim] in this step because the
Patch display defaults on entry to dimmer input.
Selects dimmers 18 through 35
Prompt reads:
Select dimmer numbers, then press
ENTER to assign to a channel, or
press AT to assign a proportion, or
press PROFILE to assign a profile
3. Press [S1], Dimmer
Double.
Sets selected dimmers to doubled
mode
Vista de pagina 61